Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features:
• AC input range selectable by switch
• Protections:Short circuit/Over load/Over voltage
• Cooling by free air convection
• 100% full load burn-in test
• Fixed switching frequency at 83KHz
• 2 years warranty
Specification:
Model |
S-75-5 | S-75-12 | S-75-15 | S-75-24 | |
Output | DC Voltage | 5V | 12V | 15V | 24V |
Rated Current | 12A | 6.3A | 5A | 3.2A | |
Current Range | 0~15A | 0~6.3A | 0~5A | 0~3.2A | |
Rated Power | 75W | 75W | 75W | 75W | |
Ripple & Noise (max.) | 120mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | |
Voltage Adj. Range | 4.75~5.5V | 10.8~13.2V | 13.5~16.5V | 21.6~26.4V | |
Voltage Tolerance | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load Regulation | ±1.0% | ±0.5% | ±0.5% | ±0.5% | |
Setup,Rise time | 300ms, 50ms/230VAC 800ms, 50ms/115VAC at full load | ||||
Hold time (Typ.) | 80ms/230VAC 12ms/115VAC at full load | ||||
Input | Voltage Range | 85 ~ 264VAC 120 ~ 370VDC | |||
Frequency Range | 47~63HZ | ||||
Efficiency(Typ.) | 79% | 84.5% | 86% | 88.5% | |
AC Current(Typ.) | 2A/115VAC 1A/230VAC | ||||
Inrush Current (Typ.) | COLD START 20A/115VAC 40A/230VAC | ||||
Leakage Current | <3.5mA / 240VAC | ||||
Protection | Over Load | 105 ~ 150% rated output power | |||
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
|||||
Environment | Working Temperature | -10 ~ +60°c (Refer to "Derating Curve" ) | |||
Working Humidity | 20~90% RH Non-condensing | ||||
Storage temp.& humidity | -20~+85°C, 10~95%RH | ||||
Temp. coefficient | ±0.03%/°C (0~50°C) | ||||
Vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |
||||
Others | MTBF | 316.2K hrs min. MIL-HDBK-217F (25°c ) | |||
Dimension | 159*97*38mm (L*W*H) | ||||
Packing | 0.51Kg; 30pcs/15.3Kg/0.7CUFT |